 ST-100MW-T Series Moisture Analyzer  Mode ST-100MW-T Range (g) 110g Readability(g) 0.001g Operating Temp 5℃-35℃ Pan Size Ø 90mm   Heat Source   Halogen Lamp Temp.Sensor PT 100 Temp. Range 40℃-199℃ Temp.Step 1℃   Moisture Range 0.00%-100.00% Moisture Readability 0.01% Dry Residual Range 100.00%-0.00% Dry Residual Readability 0.01%   Temp Setting 40℃-199℃ By 1℃ Step Time Setting 1-99min by 10 s   Numbe...


  • FOB price: $350-$600
  • Min.Order Quantity: 1 Piece/Pieces
  • Supply Ability: 3000Piece/Pieces per Month
  • Port: Qingdao/Shanghai
  • Payment Terms: L/C,D/P,T/T
  • Product Detail

    Product Tags

     ST-100MW-T Series Moisture Analyzer 
    Mode

    ST-100MW-T

    Range (g)

    110g

    Readability(g)

    0.001g

    Operating Temp

    5℃-35℃

    Pan Size

    Ø 90mm

     
    Heat Source

      Halogen Lamp

    Temp.Sensor

    PT 100

    Temp. Range

    40℃-199℃

    Temp.Step

    1℃

     
    Moisture Range

    0.00%-100.00%

    Moisture Readability

    0.01%

    Dry Residual Range

    100.00%-0.00%

    Dry Residual Readability

    0.01%

     
    Temp Setting

    40℃-199℃ By 1℃ Step

    Time Setting

    1-99min by 10 s

     
    Number Of  Storage

    20

    Number Of  History

    20

     
     Heater

    220V ±15%  50HZ

    400W

    Balance

    Input: 220V 50HZ

    Output:9V

    Host Dimension

    360X490X350mm

    The Chamber Height

    22mm

     Display

    5 inch touch panel

    Calibration

    External Calibration

    Interface

    RS232

    Use halogen moisture analyzer should attention:
    1,halogen moisture analyzer is used to measure the moisture content in the sample,

    used for any other purpose are likely to cause harm and personal damage the instrument.
    2, Please read the instructions carefully before you use it, do not use it under the environment

    condition which not meet the requirements.
    3, halogen rapid moisture analyzer only suit for professional operate.
    4, halogen rapid moisture analyzer for power for the three plug with earthing socket,

    banned disconnect apparatus grounding or use without a good grounding power supply.
    5, Instrument around should ensure that there is enough space, so as to avoid heat accumulation and heat.
    6, Please do not put flammable and explosive goods around the instrument.
    7, After the test, the heating unit and the container is still very hot, so please do not touch it.
    8, Toxic substances testing should be under ventilation environment